Diagnosing SCSI problems is best done in a logical fashion. It is next to impossible to figure out exactly what is causing a problem if you have everything connected... so the best way to diagnose a problem is to simplify your test setup. This is done by disconnecting everything and starting with only one device connected. Working with one device at a time is much easier than trying to figure out what is going on when you have multiple devices connected with multiple cables and terminators. What we will do first is to take the host computer and connect a cable and a known working drive. The Active Diagnostic Terminator should be connected to the drive. (See Diagram 5.) Diagram 5
Test All Cables After testing all the cables, visually inspect them to make sure the contacts are all straight and clean. Make sure there is no obstruction keeping any of the contacts from making a good connection. Check around the strain relief area for any cracks or breaks, (See Diagram 6.) Diagram 6
If you find any kind of oxidation on the cable contacts use a pencil eraser to clean them, but do not rub too hard or you will remove some of the gold plating on the contacts. Check all the connectors on any target devices. Again, if you find the connectors oxidized clean them gently with a small pencil eraser making sure to remove any residue left from the eraser. Check for cracks and breaks around the strain relief. To promote longer life try not to bend the cable too much. The strain relief can only do so much to protect your cable. Test All Target Devices Now that the cables have been tested you can next test all the SCSI Target Devices. The first thing to do before testing the hardware is to make sure that your operating system is not creating problems. Quite often the problems associated with SCSI are software conflicts. Since we are only testing hardware right now we must make it as simple as possible. So it's now time to remove all INITs (Macintosh), rename CONFIG.SYS and AUTOEXEC.BAT (Dos), and start with a fresh KERNEL (UNIX). The goal here is to test with only the basics. After you have removed, changed, recopied, all the unnecessary items in your operating system, boot the system a couple of times without any external SCSI devices connected. Make sure that you have removed all device drivers and items that might cause conflicts. Now load in only the necessary device drivers that will allow you to test the target device that you will be connecting. You will again be testing one device at a time. Use one of the known good cables that you previously tested, and connect the suspect target device. (See Diagram 7.) Diagram 7
Connect the Diagnostic Terminator and power up the computer only. Check the LED on the terminator and make sure that the TRM (Termination Power) LED lights up. If it does not, the computer is not supplying termination power. Check with the manufacturer of the computer or host adapter for service advice. (Some host adapters have removable fuses that can be replaced by the end user. Take a look at the card to see if there is a removable fuse. Replace it and repeat the previous procedure.) Now with the computer turned off, turn on the suspect target device. The TRM (Termination Power) LED should come on. If it does not, the drive fuse has also probably gone out. Call the manufacturer for details on how to fix the problem. If the LED goes on we can now proceed to the next step. With both the host and target supplying termination power we can now turn them both on and try to operate the suspect device. Data transfers are the best way to tell if a device is working or not. If the device is a hard drive, tape drive, removable drive, floptical drive, or any other device that stores information, the simplest thing to do is copy over a few megabytes of information. It is best to test data-transfers with a freshly formatted device that has been tested for bad blocks and is free of viruses. It is also useful to test a target device for a prolonged amount of time, thus testing for thermal problems that will only arise after hours of testing. If the device does not have any problems after such testing you can feel reasonably assured that the drive is operating properly. So, if possible, reformatting the device is a good safeguard against viruses and bad blocks. Both can create problems. Using the Diagnostic Terminator to help check how things are working can be done very easily. During the data-transfer state, you should be able to monitor the ACK (Acknowledge Line) LED, the REQ (Request Line) LED and the SEL (Select Line) LED. Both the ACK and REQ should be glowing dimly (actually flashing on and off very fast), and the SEL line should be on brightly. If this is not the case, then you have a problem with the host or target. Refer to our section on page 6 for more details. Continue until all the SCSI targets have been individually tested. At this point you have tested all the SCSI components on your system. Now connect one device at a time and test the system as you add each device. If the system still fails as you add the last device then SCSI Cable quality should be suspect.
Copyright Jetsoft Development Company 1997-2006 |